Elektror S-HP serie Betriebs- Und Montageanleitung Seite 15

Edelstahl hochdruckventilatoren
Vorschau ausblenden Andere Handbücher für S-HP serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

www.elektror.com
Installation type D
Fan is connected on the intake and pressure side
Sealed fan
A different zone is permit-
ted inside and outside the
fan
Temperature classes:
The devices are divided into classes of maximum permissible
surface temperatures in accordance with Directive 2014/34/
EC (temperature classes). The specifi cation regarding the
temperature class is indicated on the rating plate of the de-
vices. The specifi cation regarding the class of the highest
permissible surface temperature is understood to be operat-
ing the device for its intended purpose.
Examples of identifi cation:
II 2G Ex h IIB T4 Gb
II 3D Ex h IIIC T135°C Dc
II 3G Ex h IIB T4 Gc
II 3D Ex h IIIC T135°C Dc
The complete fan has a motor and fan rating plate.
The ATEX marking on the fan rating plate applies to the
complete fan.
Example
Fan
Tempera-
T3
ture class
Equipment
3G
category
Leading marking
for the complete fan: T3
3G
Certain applications and operating conditions may increase
the hazard potential and must be communicated in advance
to Elektror and agreed upon with Elektror.
1.2 Normal installation positions
• The fans are only approved for installation indoors.
Outdoor installation is only permitted with suitable
weather protection for the complete fan.
• Ensure that the installation situation does not affect the
ventilation system of the drive motor.
Minimum distance to the blower cover
(for the intake of cooling air)
Blower model
Up to S-HP 290
From S-HP 365
Operating and assembly instructions S-MP ATEX
Open fan
The same potentially explo-
sive atmosphere prevails
inside and outside the fan
Motor
T4
2GD
Minimum distance
to the blower cover
[mm]
[inches]
34
1.34
53
2.09
Secure the fan fl ange, base and console so that they lie
fl at.
The following installation positions are permitted for the
fans:
Installation position with a horizontal motor shaft:
Note!
The motor shaft with a horizontal motor shaft is
recommended by the manufacturer.
mit Fuß
Up to and including:
no restriction
Temperature and ambient conditions
max. temperature min. temperature
Flow medium
temperature at the
+60°C
intake
Ambient tempera-
+40°C
ture
• Avoid aggressive ambient conditions, high air humidity or
strong temperature fl uctuations which may lead to
condensation forming on the motor/blower.
Intended use includes:
• The blowers are exclusively designed for conveying
gaseous media without solids. The resistance should be
checked against the used steel sheet for operation with
aggressive media. We recommend a condensed water
borehole at the lowest point in the housing in the event of
the formation of condensation.
• S1 operation (continuous operation)The blower is funda-
mentally designed for S1 operation (continuous opera-
tion).
• Auxiliary heating is also possible with individual models
(only category Ex db eb II 2G T4 135°C).
• Device category 2G and 3G:
The medium to be conveyed and the environment do not
contain substances that may corrode materials, such as
acids, alkaline solutions, solvents, aggressive or abrasive
gases, liquids or solids. The medium to be conveyed is
free of depositing, sticky or condensing substances and
foreign objects.
• Device category 3D:
The medium to be conveyed and the environment do not
contain substances that may corrode materials, such as
acids, alkaline solutions, solvents, aggressive or abrasive
gases or liquids. The medium to be conveyed is free of
sticky or condensing substances and foreign objects.
• Fans with motors in accordance with ignition protection
type Ex db eb are only suitable for frequency converter
operation with a rated voltage of ± 5%
• The values for the maximum/minimum frequency can be
found at 3.3.1.
EN
mit Konsole
-20°C
-20°C
15