• Detecting worn out surge protective devices:
SPD is wired to a digital input of the Transclinic, the Modbus client can detect SPD
cartridges that reached the end of their life.
• Detecting DC switch-disconnectors status:
accidentally left open after a maintenance session (a switch-disconnector with a dry
contact must be used).
• Detecting combiner boxes with internal hot spots:
measurement function of the Transclinic, an accidental hot spot (i.e. a loose
connection) inside a combiner box can be remedied before it becomes a fire accident.
• Prioritizing maintenance actions:
maintenance staff can better decide what tasks in the DC side have higher priority
due to the lost energy production or the risk level.
DANGER
If the Transclinic is used in a manner not specified by Weidmüller, the
protection provided by the equipment may be impaired.
WARNING
This equipment shall not be used for measurements on mains circuits.
For detailed ratings of the PV-side terminals please check the corresponding
section in this user guide as well as the product specifications in the annex.
Failure to observe this requirement will create an electric shock hazard.
NOTICE
Even though DC-side power and energy measurements can be derived
from the measurements taken with this equipment, the Transclinic is not
intended to be a power meter or an energy meter.
if the remote alert of a Weidmüller
thanks to the temperature
by combining all the measurements above, the