Herunterladen Inhalt Inhalt Diese Seite drucken

Symbols Used; Technical Data - Truma Saphir comfort RC Einbauanweisung

Staukastenklimaanlage und heizung in einem
Vorschau ausblenden Andere Handbücher für Saphir comfort RC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Saphir comfort RC air conditioning system
Table of contents

Symbols used ........................................................................ 7

Technical data ..................................................................... 7

Installation instructions
Scope of delivery ................................................................... 8
Intended use .......................................................................... 8
Regulations ............................................................................ 8
Selecting a location ........................................................... 8
Installation dimensions .......................................................... 8
Installing the air conditioning system ............................ 9
Air distribution ....................................................................... 9
Circulated air return ............................................................. 10
Installing the IR receiver ................................................. 10
230 V electrical connection and
connection of IR receiver ................................................ 10
Function test /
IR remote control mounting ................................................ 10
Symbols used
The device must only be installed and repaired by an
expert.
Symbol indicates a possible hazard.
Note containing information and tips.
Technical data
Determined on the basis of EN 14511 or Truma test conditions
Designation
Saphir comfort RC, comfort air conditioning system
Number of structural units
1
Dimensions L x W x H
628 x 400 x 290 mm
Weight
approx. 23.5 kg
Power supply
230 V – 240 V ~, 50 Hz
Maximum cooling power
2.4 kW
Heating power
1.7 kW
Effective power consumption
0.98 kW
Starting current
20 A (150 ms)
Power consumption
4.2 A / 35 °C
Protection class:
IP X5
Energy Efficiency Rate (EER)
2.4
Volume flow (cold air)
max. 380 m³/h
Refrigerant
R 407C / 0.45 kg
Contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Hermetically sealed.
Global warming potential (GWP)
1774
CO2 equivalent
798.3 kg
Compressor oil
Diamond MA32, 300 cm³
Noise
depending on installation situation
Maximum incline of vehicle during
operation
5° / 8 %
Usage limits
+4 °C to +43 °C.
– An interior air sensor prevents the compressor from operat-
ing at temperatures of less than +16 °C during cooling.
– An anti-freeze sensor prevents non-permitted ice formation
on the evaporator coil.
– A temperature switch prevents excessive current and tem-
perature at the compressor.
E24 10R-040991
Right reserved to make technical changes!
EN
7

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Saphir compact

Inhaltsverzeichnis