Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Of The Indoor Unit - Klarstein Windwaker Eco Bedienungsanleitung

Split-klimaanlage
Vorschau ausblenden Andere Handbücher für Windwaker Eco:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
Charge
amount (kg)
Floor location
Minimum
Window
room
mounted
area (m
)
2
Wall
mounted
Ceiling
mounted
80

INSTALLATION OF THE INDOOR UNIT

Important installation instructions
WARNING
Risk of injury! All persons involved in the installation of the air
conditioning system MUST have the valid certifi cation of the responsible
authority and the qualifi cation recognised by this industry for handling
the refrigeration system.
• If other technicians are required for the maintenance and repair of the unit, they
should be supervised by the person who has the qualifi cation for the use of the
combustible refrigerant.
• The air-conditioning system must only be repaired in accordance with the procedure
laid down by the manufacturer of the appliance.
• The air conditioner must not be operated in rooms with open fl ame devices (such as
fi replaces, running coal-gas appliances, running heaters, etc.).
• It is not permitted to drill into or expose the connecting pipe to fi re.
• The air conditioner must be installed in a room larger than the specifi ed minimum
room size. The minimum room size is indicated on the nameplate or in the following
table a.
• A leak test must be carried out after installation of the unit.
Minimum room size (m
≤ 1,2
1,3
1,4
1,5
/
14,5
16,8
19,3
/
5,2
6,1
7
/
1,6
1,9
2,1
/
1,1
1,3
1,4
)
2
1,6
1,7
1,8
1,9
22
24,8
27,8
31
7,9
8,9
10
1 1,2
2,4
2,8
3,1
3,4
1,6
1,8
2,1
2,3
2
2,1
2,2
2,3
34,3
37,8
41,5
45,4
12,4
13,6
15
16,3
3,8
4,2
4,6
5
2,6
2,8
3,1
3,4
2,4
2,5
49,4
53,6
17,8
19,3
5,5
6
3,7
4

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis