Herunterladen Inhalt Inhalt Diese Seite drucken

Klarstein Windwaker Eco Bedienungsanleitung Seite 84

Split-klimaanlage
Vorschau ausblenden Andere Handbücher für Windwaker Eco:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
84
Installing the unit in the following locations may result in malfunction of the unit. The
following locations are not suitable for installation. If installation in any of these locations
cannot be avoided, contact customer service before installation:
• Locations with strong sources of heat, vapors, flammable or explosive gases, or
volatile objects dispersed in the air.
• Places where high frequency equipment is used (such as welding machines,
medical equipment, etc.).
• Places near the coast.
• Places where there are oils or vapours in the air.
• Places where sulphurous gases escape or are present.
• Places with similar conditions to those mentioned above.
• The unit must not be installed in washrooms.
• The unit must not be installed on unstable or moving structures (such as a truck) or in
corrosive environments (such as a chemical plant).
Step 1: Determining the Location
Recommend an installation location to the customer and then coordinate the exact
installation location with the customer.
Step 2: Installing the Wall Suspension
1
Hang the wall suspension from the wall and adjust it with the spirit level in the
horizontal position. Mark the screw mounting holes on the wall.
2
Drill the screw fixing holes with a percussion drill (the drill head should have the
same properties as the dowels) and then insert the dowels into the holes.
3
Fix the wall suspension with the tapping screws (ST 4.2 x 25 TA) and then pull on
the wall suspension to ensure that it is tight and properly installed. If a dowel is
loose, drill another hole nearby.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis