Herunterladen Inhalt Inhalt Diese Seite drucken

Appliance Description; Operation; Temperature Selector; Frost Protection - STIEBEL ELTRON SHU 10 SLi Bedienung Und Installation

Vorschau ausblenden Andere Handbücher für SHU 10 SLi:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
HTV`.HC
TT<.C ZV.T`.HC
3.

Appliance description

The appliance constantly keeps the water content available at the
preselected temperature.
The DHW outlet temperature can be variably adjusted at the
temperature selector. The output is switched on automatically as
soon as the appliance temperature falls below the selected value.
Upon request, your local contractor can set a temperature
selection limit; see chapter "Installation / limiting the temperature
selection".
The appliance is under mains water pressure. The
volume of water expands as the water heats up. During
this process, expansion water drips through the safety
valve. This is a necessary and normal process.
4.

Operation

4.1

Temperature selector

You can select whichever temperature you require at the
temperature selector.
The ON / OFF indicator illuminates while the water is being heated.
SHU ...
2
1
1 Temperature selector
2 Indicator
Depending upon the system, the temperatures may vary from
the set value.
4.2

Frost protection

This appliance is equipped with a frost protection stage "°C" (cold).
In this position, the appliance is protected against frost. The tap
and the water line are not protected.
4.3

Economy setting

This appliance is equipped with an economy setting "Eco". At this
setting, minor scaling inside the appliance will occur.
4.4

Heat-up time / Outlet volume

Subject to season, different maximum mixed water or outlet
capacities can result from varying cold water temperatures. For
further information regarding these, see chapter "Specification /
Data table".
Ô
’Z+e ’ Z+
5.

Cleaning, care and maintenance

ª Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
ª Check the taps regularly. You can remove limescale deposits
at the tap outlets using commercially available descaling
agents.
ª Have the electrical safety of the appliance and the function
of the safety assembly regularly checked by a heating
contractor.
ª Have the protective anode checked by a heating contractor
after the first 8 years. The heating contractor will then
determine the intervals at which it must be checked
thereafter.
6.

What to do if ...

6.1

... the appliance develops faults

%| ù
The appliance fails to
deliver hot water.
SH ...
Water can only be
1
drawn at a reduced
rate.
Loud boiling noises
2
inside the appliance.
Water drips from the
safety valve of the
safety assembly after
heating has stopped.
Where a contractor is required, they can remedy the fault more
quickly and effectively if you provide the following details from
the appliance type plate:
|
¼
á V¼ ¼®
The temperature
Switch the appliance ON
selector is set to
by turning the temperature
"OFF".
selector.
There is no power.
Check the fuse/MCB in your fuse
box/distribution panel.
The jet controller in
Descale or replace the jet
the tap is scaled up.
controller.
Appliance scaled up. Have a contractor descale the
appliance; contact customer
service.
The safety valve is
Switch the appliance OFF and
scaled up or dirty.
depressurise it by isolating it
from the power supply and
shutting off the water supply.
Have a contractor check the
safety valve; contact customer
service.
............