6.2.2 Linearity control setting

6.2.3 Calibration stick value setting

64
This menu allows you to preselect whether a routine check of the indicating accuracy
(linearity control) is required before the first measurement with the emission system
analyzer or the emission analysis measuring instrument.
i Linearity control is specific to the particular country, as is the interval (in days)
between the linearity control procedures.
This menu allows you to enter the calibration stick values from 0 % to 99.9 %.
Normally, the calibration stick value is around 50 %, but the actual values differ from
country to country. If necessary, these values can be changed in this menu.