en
Nozzle type
Nozzle type
Nozzle type
Gas type
Gas type
Gas type
PL - Category: II
Natural gas E
Primary pressure 20 mbar
(PL)
Liquid gas 3B/P
Primary pressure 29/37 mbar
(PL)
7.2
Outer nozzle replacement
7.3
Replacing the pilot burner nozzle
Pilot burner
nozzle
Screw connection
for gas line
34 / 68
Outer nozzle
Refer to page 34, chap
ter 7.2
2E 3B/P
ø 1,65 mm
ø 1,10 mm
Threaded pin
Connector
Outer nozzle
Pilot burner
Spark plug
Pilot burner nozzle
For pilot burner nozzle repla
cement, refer to page 34,
chapter 7.3
Pilot burner nozzle with two
bores of ø 0.25 mm each
ø 0,20 mm
. Loosen the threaded pin until the connector
can be withdrawn.
. Withdraw the connector.
. Replace the outer nozzle, refer to the data
stated in the table on page 32, chapter 7.1
. Insert the connector down to the limit stop
and secure it by means of the threaded pin.
. Check all gas-bearing components for the
leak tightness.
. Unscrew the spark plug to protect it against
any damage during the conversion process.
. Screw out the gas line to the pilot burner.
D Caution, the pilot burner nozzle may fall out!
. Replace the pilot burner nozzle, refer to the
data stated in the table on page 32, chap
ter 7.1
Risk of breakage! The spark plug may
be damaged by excessive fastening. Therefore,
fasten the spark plug only lightly!
. Check all gas-bearing components for the
leak tightness.