Nozzle type
Nozzle type
Nozzle type
Gas type
Gas type
Gas type
NL - Category: II
2L 3B/P
Natural gas L
Primary pressure 25 mbar
(NL)
Liquid gas B/P
Primary pressure 30 mbar
(NL)
SE - Category: III
1ab 2H 3B/P
Twon gas ab
Primary pressure 8 mbar
(SE)
Natural gas H
Primary pressure 20 mbar
(SE)
Liquid gas B/P
Primary pressure 30 mbar
(SE)
DK - Category: III
1e 2H 3B/P
Twon gas ab
Primary pressure 8 mbar
(DK)
Natural gas H
Primary pressure 20 mbar
(DK)
Liquid gas B/P
Primary pressure 30 mbar
(DK)
NO - Category: III
2H 3B/P
Natural gas H
Primary pressure 20 mbar
(NO)
Liquid gas B/P
Primary pressure 30 mbar
(NO)
Outer nozzle
Refer to page 34, chap­
ter 7.2
ø 1,65 mm
ø 1,10 mm
ø 3,10 mm
Increasing burner spacing
via spacer, see page 35
section 7.4
ø 1,65 mm
ø 1,10 mm
ø 3,10 mm
Increasing burner spacing
via spacer, see page 35
section 7.4
ø 1,65 mm
ø 1,10 mm
ø 1,65 mm
ø 1,10 mm
Pilot burner nozzle
For pilot burner nozzle repla­
cement, refer to page 34,
chapter 7.3
Pilot burner nozzle with two
bores of ø 0.25 mm each
ø 0,20 mm
ø 0.80 mm
Pilot burner nozzle with two
bores of ø 0.25 mm each
ø 0,20 mm
ø 0.80 mm
Pilot burner nozzle with two
bores of ø 0.25 mm each
ø 0,20 mm
Pilot burner nozzle with two
bores of ø 0.25 mm each
ø 0,20 mm
33 / 68
en

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Master typ 810 serie

Inhaltsverzeichnis