Instructions Behnke IP camera
GB
GB
Introduction
1.7. Connecting the IP camera with B-Smart function in conjunction with the Behnke
a/b door intercom series 20 (20-/21-/50-2907A-IP, 43-9587A, 50-1204A/-1207A)
▸
IP camera with B-Smart function (20-/21-/50-2907A-IP, 43-9587A, 50-1204A/-1207A) in con-
junction with an analogue Behnke door intercom series 20 (20-0001/-0002/-0005/-0006/
*
-0013
/-0014/-0041
▸
The camera with B-Smart function only supports video and a open door function via app.
▸
Camera power supply through POE class 0
or
Network
Voltage supply on site.
Important: Observe the relay switching capacities in the camera specifications and the ana-
logue intercom.
*
2
1. Connect the two-wire cable with MQS
plug to the jack for button 8 on the ribbon
cable (T8).
2. Configuring the door station: enter configu-
ration mode: *0000, configuration for button
8: 28, *71# (for door opening via relay 1),
50
*
/-0043)
The connection to the
analogue door station is
*
2
required for door opening
via app or IP video software
(with licence). Caution:
in this case you can only
connect 7 call buttons!
*
1
Connecting cable
between the IP
camera with B-Smart
function and the
Behnke a/b intercom
relay cannot exceed
50 cm
Open door
function
or *72# (for door opening via relay 2), or *73#
(for activation of both relays)
For information on how to configure the door station's relays
please see the documentation of your device!
a/b line
www.behnke-online.com