In combination with the CRS 845 tester set and the CP 3.x supplementary equipment set

8
7
5
6
9
4
1
2
3
Figure 3: Hydraulic connection
Procedure:
1. Connect the lubricating oil supply (1) and lubricating oil return (2) lines.
2. Connect the supply (3) and return (4) of the pre-delivery pump.
3. Connect the supply (5) of the metering unit (FMU) with the temperature sensor (6).
4. Connect the high-pressure outlets (7).
5. Connect the pump overflow (8).
6. Connect the temperature sensor (6) with the connector cable (9) to the BNC socket
of the KMA 802 measuring device.