Herunterladen Inhalt Inhalt Diese Seite drucken

Hydraulic Connection; In Combination With The Crs 845 Tester Set - Bosch CP 2 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
6.

Hydraulic connection

! Note the test and repair instructions for high-pressure
pumps in the ESI[tronic].
! When connecting the high-pressure hoses (6)
make sure the following tightening torques are adhered to:
Pump side
20 - 25 Nm
Rail side
30 Nm
6.1

In combination with the CRS 845 tester set

1 2
Figure 2: Hydraulic connection
Procedure:
1.
Connect the lubricating oil supply (1) and lubricating oil return (2) lines.
2.
Connect the supply (3) and return (4) of the pre-delivery pump.
3.
Connect the supply (5) of the metering unit (FMU) with the temperature
sensor (6).
4.
Connect the high-pressure outlets (7).
5.
Connect the pump overflow (8).
6.
Connect the temperature sensor (6) with the connector cable (9) to the BNC
socket of the KMA 802 measuring device.
10
7
8
5
4
6
3
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis