INSTALLATION

Installation
10. Installation

Standard installation

- Electrical connection in upper part of appliance
For further installation options, see chapter "Installation /
Installation options":
- Adjustable connected load
- Anti-scalding protection / temperature limit
- Electrical connection in the lower section of the appliance
10.1 Standard installation
Appliance installation
Note
f Mount the appliance on a wall.
f
The wall must have a sufficient load-bearing capacity.
f Undo the snap fastener using a screwdriver.
f
f Remove the appliance front cover by pulling it forwards.
f
1
2
1 Upper fixing screw
2 Lower fixing screw
f Mark out the 3 holes to be drilled using the installation tem-
f
plate (see centre section of these instructions).
f Drill the holes. Use suitable rawl plugs and round head or
f
cylinder head screws with 8 mm screw head diameter. The
screws and rawl plugs are not part of the standard delivery.
f Insert the upper screw to the depth indicated.
f
f Hook the appliance onto the screw. Pull the appliance
f
downwards.
f Tick the selected connected load and voltage on the type
f
plate.
f Align the appliance horizontally. Then insert the lower 2
f
screws.
26
|DCE 11/13| DCE 11/13 RC| DCE 11/13 H
5,5 - 6,5
Water connection
Material losses
!
For the appliance to function correctly, the strainer must
be built into the cold water inlet.
Tap installation
f Install the tap. For this, also observe the tap operating and
f
installation instructions.
Material losses
!
f When making the connections, counter the torque
f
on the appliance using an appropriate spanner.
Note
Only in the case of pressure-tested connections
DCE 11/13 | DCE 11/13 RC:
f Fit the 3/8 connection hose and the 3/8 tee provided.
f
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Ensure that the appliance is earthed.
Ensure the appliance can be separated from the power
supply by an isolator that disconnects all poles with at
least 3 mm contact separation.
WARNING Electrocution
The appliances are delivered equipped with a power
cable.
Connection to a permanent power supply is possible,
provided the cross-section of the fixed cable is at least
equal to that of the standard power cable for the ap-
pliance. The maximum permissible cross-section is
4 x 6 mm².
Material losses
!
Observe the type plate. The specified voltage must match
the mains voltage.
f Connect the power cable in accordance with the electrical
f
connection diagram (see chapter "Installation / Specifica-
tion / Wiring diagram"). There is a choice between 2 con-
nected loads. The high load is preset. If selecting a different
output, see chapter "Installation / Installation options / Ad-
justable connected load".