BML SF2-I2 _ _ -A/QZ _ _ - Z _ _ 5-...
Incremental magnetic encoder system
1
Notes to the user
1.1
Validity
This guide describes the construction, function and
installation options for the BML incremental magnetic linear
encoder. The guide applies to the
BML SF2-I2 _ _ -A/QZ _ _ - Z _ _ 5-KA/KD/KF _ _ and
BML SF2-I2 _ _ -A/QZ _ _ - Z _ _ 5-KA_ _-S284 sensor
head series (see type code on page 28 and 29).
This guide is intended for qualified technical personnel.
Read this guide before installing and operating the linear
encoder.
More information on the interfaces are available
in the document titled Interfaces for BML
Magnetically Coded Position Measuring System
(see Tab. 10-2 on page 30).
1.2
Symbols and conventions
Individual instructions are indicated by a preceding
triangle.
► Instruction 1
Action sequences are numbered consecutively:
1. Instruction 1
2. Instruction 2
Note, tip
This symbol indicates general notes.
1.3
Scope of delivery
–
Sensor head
–
Condensed guide
Different variants of the magnetic tapes are
available and must be ordered separately.
www.balluff.com
1.4
Approvals and markings
UL approval
File no.
E227256
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
The transducer meets the requirements of the following
product standard:
–
EN 61326-2-3 (noise immunity and emission)
Emission tests:
–
RF emission
EN 55011
Noise immunity tests:
–
Static electricity (ESD)
EN 61000-4-2
–
Electromagnetic fields (RFI)
EN 61000-4-3
–
Electrical fast transients (burst)
EN 61000-4-4
–
Surge
EN 61000-4-5
–
Conducted interference induced by
high-frequency fields
EN 61000-4-6
–
Magnetic fields
EN 61000-4-8
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
Severity level 4
Severity level 3
Severity level 4
Severity level 2
Severity level 3
Severity level 4
english
5