Note:
For measuring internal dimensions, the red and yellow indicators can be switched
over by reversing the order in which the tolerance limits are input (lower limit >
upper limit).
It is possible to input different tolerances on REF1 and REF2.
It is also possible to display the tolerance limits when the instrument is operating
in MIN, MAX or DELTA (TIR) mode.
If no tolerance limits have been defined by the user, the instrument will display the
tolerance limits have indicators
(red - green - yellow)
3.6. Favourite key
The «favourite» key gives direct access to a predefined function, and can be
configured according to the needs of the user. In order to assign a function to
the «favourite» key.
Give a prolonged press on ,
OK
and then select the required function :
Data transmission
(default)
Hold display
Re-initialise
Min-Max-Delta
Zero reset
11
Input the lower tolerance limit
Input the upper tolerance limit
next digit
SET
, but will not turn on the indicator lights
0...9
save TOL
MODE
REF1 - REF2
Recall Preset
Nor–Min–Max-Delta
Tol ON–Tol OFF
E
bt
b