CD- Slot:
Slot to inspect the coolant fluid level.
CE - Cap.
CF - Quick-fitting valves:
Connect the red and blue hose of the welding torch. NB
Match the hose and valve colors correctly.
CG - Quick-fitting valves:
This is where the red and blue hoses coming off the power
source/trolley connection must be connected in machines
with separate wire feeder. NB Match the hose and valve
colors correctly.
CH – Fuse holder.
CI - Connection.
For coolant pressure protection.
CL - ON/OFF switch.
CM - Power cable.
4.1 WIRING.
For the extensions and protection devices wiring follow
the directions of the instruction manual provided with the
cooling unit.
4.2 DESCRIPTION OF PROTECTION DEVICES.
4.2.1 Coolant pressure protection device.
This protection is achieved by means of a pressure
switch, inserted in the fluid delivery circuit, which controls
a microswitch. If the pressure is insufficient, the display
shows the wording H2O flashing.
4.2.2 Fuse (T 2A/250V - Ø 5x20).
This fuse protects the motor pump, and is located in the
fuse holder CI on the rear panel of the welding machine.
(Fig. 12)
4.3 START UP.
Unscrew the cap CE and fill the tank (the equipment is
supplied with approximately one liter of fluid).
It is important to periodically check, through the slot CD,
that the fluid remains at the "max" level.
14
PLEASE NOTE: THE PICTURES USED IN THIS
MANUAL AND IDENTIFIED BY A NUMBER CAN BE
CONSULTED IN THE ENCLOSED BOOKLET CODE
3301039
5 DISPLAY DESCRIPTION
the software was updated, the options installed and the IP
address.
The display then presents the main screen (factory
setting).
The operator may start welding immediately and may
adjust the current by turning knob AN.
As seen in the figure, the display is divided into sectors. In
each sector, settings operations may be conducted. The
main sector DB is the only one with a red frame. To select
and enable the functions in this sector, press the knob
AN, choose the function you wish to modify by turning
the knob and the selected functions will turn blue. The
name of the selected function will be displayed on the
upper left.
The welding process always appears in the upper left
between sectors DB and DC.
DC
DB
DM
DL
When the function is highlighted in blue, simply press
the knob and the function will turn red. A cursor will be
displayed indicating the minimum, maximum and set
values. To change this value, set it using the knob; to
confirm it, press the knob again. All the other sectors are
selected simply using your finger.
During start-up,
for 5 seconds
the display pre-
sents all the in-
formation
garding
machine,
serial number,
the
version,
DG
DI
DH
re-
the
the
software
when
DD
DE
DF