Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Elements; Items Supplied; Commissioning; Setting The Time - Silvercrest KH 1159 Bedienungsanleitung

Digitale küchenwaage
Vorschau ausblenden Andere Handbücher für KH 1159:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
Injury hazard
• Keep batteries away from children. Children can
put batteries into their mouths and swallow them.
If a battery is swallowed, medical assistance
must be sought immediately.
• Should a battery leak, avoid making contact to
the leakage with your skin, eyes and mucous
membranes. If contact is made with the battery
acids, rinse the affected area with copious
amounts of water and then consult a doctor.

Operating Elements

q
Battery compartment
w
Display
e
Mounting for suspension
r
T-SET button (Timer/Clock adjustment)
▼ UNIT button (Unit adjuster)
t
▲ Z/T button (ZERO/TARA)
y
u
ON/OFF button
i
Glass plate
o
Bowl

Items supplied

• Kitchen scales
• Bowl
• 2 x CR 2032 Lithium batteries
• 2 x Screws
• 2 x Plugs
• Operating Instructions

Commissioning

➩ Open the battery compartment
the operating panel.
➩ Remove the protection strip from the battery
q
compartment
.
➩ Close the battery compartment cover, until it locks
in place.
The scale is now in clock mode and ready for use.

Setting the time

On commissioning and on a change of batteries the
time must be set resp. adjusted.
➩ As soon as the batteries have been inserted the
➩ Press the T-SET button
➩ Press either the ▲ Z/T
➩ Press the T-SET button
The time display is now programmed.
If you need to re-adjust the time display (e.g. for
Summer/Winter Time) press and hold the T-Set
button
as described above.

Wall mounting

➩ Find a suitable position for the wall assembly.
Check to ensure that there are no power cables
located in the wall. Should you bore into a power
cable with the drill, you may receive a potentially
fatal electric shock!
Do not drill into areas where electric cables and
gas or water conduits are, or may be, located!
➩ Using a 6mm drill, bore two holes with a horizontal
➩ Insert the plugs into the holes and then screw in
q
at the rear of
➩ Place the scales onto the screw heads using the
- 27 -
hour indicator blinks. Press either the ▲ Z/T
or the ▼ UNIT
t
button repeatedly to adjust
and set the hour indicator.
r
minute indicator.
y
repeatedly to adjust and set the minute indicator.
r
r
until the hour indicator blinks. Then proceed
There must be sufficient space to fold down the
glass plate
i
. Bear in mind that the bowl
may also have to be placed on the glass plate
Attention!
spacing of ca. 88 mm into a vertical wall.
the screws until the screwheads project by about
3 - 4 mm.
mounting
e
intended for this purpose.
y
to switch over to the
or the ▼ UNIT
t
button
.
o
i
.