17. Guide the line over the roller and move the slide
until the cable is tensioned.
18. Re-attach the stand cover and laser visor to the
stand and tighten the retaining screws.
i
The laser visor must be re-calibrated after cable
replacement.
i
Refer to the Calibration section.
Robert Bosch GmbH
Component replacement | HTD 6xx, HTD 8xx | 47
Replacing wheels
!
Secure the counterweight with a locking bolt before
tilting the stand.
1. Place a sheet of paper or a large cloth on the floor to
avoid damaging the stand.
2. Lay the stand on the floor.
3. Remove the screw from the wheel.
4. Remove the wheel.
5. Fit a new wheel.
6. Secure the wheel with the screw.