8. Select Dipped beam testing on the beam setter.
9. The cut-off must be within the tolerance range.
Note down the intensity value.
10. Repeat the same test for the main beam.
11. Select "OPTIONS" in the main menu.
12. Click onto "SERVICE" in the "OPTIONS" mask.
13. Enter the PIN: 835231
14. Click onto "CALIBRATION" in the "SERVICE" mask.
15. Calculate the correction factor ("D") for the dipped
beam as follows:
i
D - Correction factor
Ikal- Specified intensity value of calibrating unit
(device label)
Iseg - Measured intensity value of beam setter
 D= (intensity value of calibrating unit)/(intensity
value of HBT)
Robert Bosch GmbH
Checking / calibration | HTD 6xx, HTD 8xx | 39
16. Alter the dipped beam value "D" by way of the + or -
arrows on the right and save the value.
17. Press the headlamp symbol to switch to main
beam.
18. Repeat items 15 and 16 for the main beam.
en
|
1 692 106 011
2014-06-23