By default, the speed controller is preprogrammed with the optimal settings.
When using LiPo rechargeable batteries to operate the vehicle, check whether low voltage protection is
enabled in the default setting of the speed controller (normally 3.0 V per cell). When low voltage detection
is disabled, LiPo rechargeable batteries are subject to a deep discharge that destroys them.
The setup button can be used to program the settings.
Proceed as follows:
• Switch on the remote control.
• Switch off the speed controller (move the switch to the
"OFF" position).
• Hold down the setup button (B) next to the on/off switch
(A) and turn on the speed controller (move the switch to
the "ON" position).
Keep holding down the setup button (B).
• The red LED on the speed controller will flash and the
motor will emit beeps (keep pressing down the setup
button).
• After a while, the green LED will flash (keep pressing down the setup button) and the motor will emit beeps. This
indicates which setup function is currently selected.
Green LED flashes once briefly and 1 short beep:
Green LED flashes twice briefly and 2 short beeps:
Green LED flashes briefly three times and 3 short beeps: Low voltage detection for the LiPo battery
Green LED flashes briefly four times and 4 short beeps:
Green LED flashes once for a long time and 1 long beep: Braking power
Beeps are generated by a brief activation of the brushless motor. This beep can be very quiet depending
on the motor. If this is the case, note the LED indication on the speed controller.
• When the setup function you want to change is displayed (for example, for low voltage protection, the green LED
flashes briefly three times and the motor emits 3 short beeps), release the setup button.
• Now the red LED will flash. The number of red flashing signals indicates which setting value is active (for example,
for low voltage protection 3.0 V per cell, red LED flashes briefly four times and the motor emits 4 short beeps).
• Briefly press the setup button to change the setting value; the number of flashing signals from the red LED (and
motor beeps) will change accordingly (see table on the next page).
• Turn off the speed controller to exit settings mode and save the programming. If you then turn on the speed
controller, it will be ready for operation with the new settings.
• Follow the above steps to change the other settings.
54
Forward/reverse throttle or forward throttle only
Brake
Startup mode