C2
Notice
When installing and operating the transducer, please
note the maximum parasitic forces - lateral forces (due to
oblique application), bending moments (due to eccentric
force application) and torques, see Chapter 12 "Specifi
cations", page 29 , and the maximum permissible load-
carrying capacity of the (customer side) force application
parts used.
7.3
Mounting
You can mount the C2 directly onto your structural ele
ments, or place it on a suitable substructure. The force
transducer measures static and dynamic compressive
forces, and can be used at full oscillation width.
Four threads are inserted underneath the C2 to allow the
force transducer to be mounted horizontally or overhead
as well.
Nominal (rated)
force
500 N...10 kN
10 kN...50 kN
100 kN...200 kN
Tab. 7.1
Horizontal or overhead mounting of the C2 force
transducer; thread dimension
A0674-5.0 HBM: public
Conditions on site
Thread size for mounting the C2
M5
M10
M12
19