Herunterladen Inhalt Inhalt Diese Seite drucken

Replace The Filter Cartridge En - Abicor Binzel FES-200 W3 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für FES-200 W3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5 Functional description
5.3 Replace the filter cartridge
After longer operating times, the fine dust penetrates into the filter and the filter becomes clogged. Even a
dedusting of the filter cannot remove this dust. The filter must be replaced by a new one.
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Disconnect the mains plug.
• Before performing any maintenance and cleaning work, suitable safety measures must be taken.
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• The personal protective equipment includes protective clothing, safety goggles, respirator mask
• Nobody without personal protective equipment may stay near the dust collecting drawer when it is
• It is not allowed to dedust the filter cartridge using compressed air.
NOTICE
• A filter change must be carried out if, after multiple dedusting, a vacuum of > 180 mbar is still
• This procedure must be carried out when the system is not in operation.
1
Place the cover on the fume extraction
system
Fig. 5
Changing the filter
EN - 16
DANGER
CAUTION
locally filtered forced ventilation.
Class P3, protective gloves and safety shoes.
being filled with the separated dust.
reached, and no other error or reason can be detected.
2
Pull the dust collecting bag over the filter
cartridge
FES-200 W3
3
Loosen the filter cartridge

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis