FES-200
5.1 Dedusting the filter
1
Compressed air connection for dedusting with the
pressure relief valve
2
Valve lever
Fig. 3
Dedusting the fine filter cartridge
CAUTION
• Check and wear your personal protective equipment.
• The personal protective equipment consists of protective clothing, safety goggles, respirator mask class P3, protective
gloves and safety shoes.
• Nobody without personal protective equipment may stay near the dust collecting drawer when filling the separated
dust into it.
NOTICE
• Use only dry and oil-free compressed air (approx. 5 - 6 bar).
• If the input pressure is > 5 bar, the excess pressure escapes sidewise through the pressure relief valve (1).
Connect the compressed air (1). Set the pressure relief valve to 5 bar and open the valve lever (2) on the compressed air
connection. Depending on the pressure, the compressed air produces a dedusting jet and causes the dedusting nozzle to
rotate inside the fine filter cartridge. The filter is cleaned by manually moving the dedusting system up and down. Empty the
separated dust from the dust collecting drawer (7) into the dust collecting bag supplied.
 Fig. 2 Functional Description on page EN-10
NOTICE
• The dust collecting drawer (7) must be emptied after every third cleaning of the filter.
Reinstall the dust collecting drawer (7) and close it.
 Fig. 2 Functional Description on page EN-12
BAL.0209.0 • 2019-08-06
1
2
3
4
3
Dedusting system
5 Functional description
4
Filter cartridge
EN - 13