5.1 Emptying the dust collecting drawer
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly and repair work:
• Switch off the power source.
• Disconnect the mains plug.
• Before performing any maintenance and cleaning work, suitable safety measures must be taken.
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• The personal protective equipment includes protective clothing, safety goggles, respirator mask
• Nobody without personal protective equipment may stay near the dust collecting drawer when it is
1
Remove the knurled nuts from the dust
collecting drawer
Fig. 3
Emptying the dust collecting drawer
Proceed as follows:
 Fig. 2 Functional description on page EN-12
1 Switch off the fume extraction system by turning the rocker switch (11) (0 position).
2 After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled
down in the fume extraction system.
3 Remove the knurled nuts (9) from the dust collecting drawer (8).
4 Carefully pull out the dust collecting drawer (8).
5 Slide the full dust collecting drawer (8) into the dust collecting bag supplied and close the bag.
6 Turn the dust collecting drawer (8) over so that the dust can fall into the dust collecting bag.
7 Carefully open the dust collecting bag and take out the dust collecting drawer (8).
8 Close the dust collecting bag tightly.
9 Clean the dust collecting drawer (8) using a damp disposable cloth.
10Clean the area into which the dust collecting drawer (8) will fit using a damp disposable cloth.
11 Slide the empty dust collecting drawer (8) into the fume extraction system.
12 Lock the dust collecting drawer (8) by screwing the knurled nuts (9) onto the fume extraction system.
DANGER
CAUTION
locally filtered forced ventilation.
Class P3, protective gloves and safety shoes.
being filled with the separated dust.
2
Pull the dust collecting drawer carefully out
5 Functional description
3
Put the dust collecting drawer in the dust
collecting bag included in the delivery and
close it
EN - 13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis