Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel FES-200 W3 Betriebsanleitung Seite 42

Vorschau ausblenden Andere Handbücher für FES-200 W3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5 Functional description
16
15
14
13
12
11
10
1
Rubber gasket
2
Turbine
3
Mounting screws
4
Compressed air connection for
dedusting
with pressure relief valve
Fig. 2
Functional description
Harmful fumes are produced during the welding process. A permanent filter located in the filter housing
removes the welding fume particles from the absorbed air. The cleaned air is led back into the work area
via the exhaust casing (12).
If the minimum volume flow is not reached, the manometer (10) indicates a high value and an acoustic
signal sounds. The filter must be then cleaned with compressed air. During the dedusting procedure, the
exhaust fume deposits are removed from the filter elements and the filter is refreshed.
The separated dust is collected in the dust collecting drawer (8).
NOTICE
• The dust collecting drawer (8) must be emptied before and after each dedusting of the filter.
• After each use, the dust collecting drawer must be checked.
• In case of a filling level of 2/3 or more, the dust collecting drawer must be emptied according to the
The FES-200 W3 is equipped with an automatic Start-Stop system. Use the start-stop pliers to switch on the
fume extraction system automatically by fixing it to the cable assembly of the welding device.
The rocker switch (11) is used to switch the fume extraction system on and off.
EN - 12
1
2
3
5
Filter cartridge
6
Extraction hose
connection
(intake fitting)
7
Seal plug
8
Dust collecting drawer
regulations.
 5.1 Emptying the dust collecting drawer on page EN-13
4
9
Knurled nuts
10 Manometer
11 Rocker switch (Manual-0-Auto)
12 Exhaust casing
FES-200 W3
5
6
7
8
9
13 Power cable connection
14 Voltage circuit breaker
15 Start-stop pliers connector
16 Counter nut

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis