2 OPTIONAL PARTS, ACCESORIES AND TOOLS

Optional Installation Parts

Part name
*1
Refrigerant piping
Putty, PVC tapes
*1 Refrigerant piping covered with insulating material (polyethylene form, 6 mm thick).
*
In case the piping is installed above the ceiling, it shall be covered with thicker insulating material (polyethylene form, 10 mm
thick).
Attachment bolt arrangement of outdoor unit
• Secure the outdoor unit with the attachment bolts and nuts if the unit
is likely to be exposed to a strong wind.
• Use φ8 mm or φ10 mm anchor bolts and nuts.
• If it is necessary to drain the defrost water, attach drain nipple to the
base plate of the outdoor unit before installing it.
Accessory and Installation Parts
Part No.
a
Outdoor unit installation manual x 1
b
Others
Important information and warning
B/W strips (Energy efficiency labels)
Specifications
Indoor unit name
Liquid side
(Abbreviation)
(Outer diameter)
10, 13
6.35 mm
16
6.35 mm
Part name (Q'ty)
Specifications x 1
Name
Gas side
(Outer diameter)
9.52 mm
12.7 mm
Elongated drain
Suction side
hole
(d)
Part No.
c
(Heat pump models only)
d
Water-proof rubber cap x 2
(Heat pump models only)
3
Q'ty
1 ea.
1 ea.
600
115
125
30
Drain hole
Diffuser
(c)
Part name (Q'ty)
Drain nipple x 1