Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba RAS-3M18SAV-E Einbauanleitung Seite 13

Multisystem-splitgerät
Vorschau ausblenden Andere Handbücher für RAS-3M18SAV-E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

01_OutdoorInstallation_EN.fm Page 11 Friday, March 23, 2007 3:05 PM
Model
Power source
Maximum running current
Installation fuse rating
Power cord
Connecting cable
CAUTION
• Incorrect wiring connection may cause electrical parts to burn out.
• Be sure to comply with local regulations/codes when running the wire from outdoor unit to indoor unit. (Size of wire and wiring
method etc.)
• Every wire must be securely connected.
• If incorrect or incomplete wiring is carried out, fire or smoke may result.
• Prepare the power supply for the exclusive use of the air conditioner.
RAS-3M18SAV-E
RAS-3M18SACV-E
220–240V ~50Hz
13.8 A
16 A breaker or fuse (all types can be used)
H07RN–F or 60245IEC66 (1.5 mm
H07RN–F or 60245IEC66 (1.0 mm
11
3 unit Multi
RAS-3M23GACV-E
220V ~60Hz
11.9 A
2
)
2
)
11.9 A
EN