WARNING
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING-TO REDUCE THE RISK OF INJURY,do not permit children to use this product unless they are closely supervised at all times.
WARNING-RISK OF ELECTRIC SHOCK- The pump must be supplied by an isolating transformer or supplied through a residual current
device(RCD) having a rated residual operating current not exceeding 30mA.
WARNING-RISK OF ELECTRIC SHOCK- The pump cannot be using while people are inside the pool.
DO NOT BURY CORD.Locate cord to minimize abuse from lawn mowers,hedge trimmers,and other equipment.
WARNING-To reduce the risk of electric shock,IF FILTER PUMP POWER CORD BECOMES DAMAGED IN ANY WAY, THE PUMP MUST BE
DISCARDED.
WARNING-To reduce the risk of electric shock,do not use extension cord to connect unit to electric supply;provide a properly located outlet.
CAUTION-This pump is for use with storable pools only.Do not use with permanently-installed pools.A storable pool is constructed so that it is
capable of being readily disassembled for storage and reassembled to its original integrity.A permanently-installed pool is constructed in or on the
ground or in a building such that it cannot be readily disassembled for storage.
IMPORTANT- Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRICAL SHOCK- When working with electricity, turn the electrical power off at the circuit breaker and lock breaker door. Failure to do
so will result in increased risk of shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE ADAPTOR PLUGS. Consult a qualified
electrician for any questions related to the validity of your plugs grounding.
Handle the pump with care. Do not pull or carry the pump by the power cord. Never pull a plug from the outlet by yanking the power cord. Keep cord
free from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the filter pump.
WARNING-This appliance is not intended for use by persons (including children) with reduced physical, sensor or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the appliance.
NOTE:
Please examine equipment before use. Notify Bestway at the customer service address listed on this manual for any manufacturing defect or missing
parts at the time of purchase. Verify that the equipment components represent the filter pump model that you had intended to purchase.
NOTE:
Place pump on a solid and level ground. Pay attention to position of pool and pump so adequate ventilation, drainage, and access for cleaning is
available. Never place pump in an area that may accumulate water, or in an area where foot traffic will flow around the pool.
It is necessary to have the plug accessible after installation of the pool.
NOTE:
Atmospheric conditions may affect the performance and life span of your filter pump. Unnecessary wear and tear may occur during periods of cold,
heat and exposure to sun. Whenever possible shelter pump from these conditions.
It is important to ensure the factory equipped stopper plugs for the inlet and outlet ports replace the screens before removal or maintenance on the
pump is attempted.
NOTE:
Do not run the pump more than 8 hours per day.
NOTE:
Do not add chemicals in the filter pump.
SAVE THESE INSTRUCTIONS.
Pump Installation Directions
PART I
Internal Filter Pump Inspection
1) Remove the Filter Cap by unscrewing the Filter Cap Retainer.
2) Inspect the Filter Cartridge ensuring it is centered in the Filter Pump.
3) After inspection, check that the Filter Cap Seal is in place, replace the Filter Cap and screw the Filter Cap Retainer into position.
PART II
Attach the Hoses to the Filter Pump and the Pool
1) Place the loose Hose Clamps on both the ends of the Hoses.
2) Attach the Hoses to the corresponding letters on both the pool and the Filter Pump (A to A, B to B).
3) Tighten the Hose Clamps to the Filter Pump by screwing the fly nut clockwise .
4) Remove the Stopper Plugs from the pool's Inlet and Outlet Valves and insert the Debris Screens.
5) With the Hoses and the Debris Screens in position, tighten the Hose Clamps.
NOTE: It is important to ensure all elements: Hoses, Debris Screens and Inlet/Outlet Valves are properly aligned.
NOTE: After pump is attached to pool, refer to pool manual for filling instructions.
Pedestal Fixing
EN60335-2-41 TEST standard requires the filter pump must be vertically fixed on ground or a certain pedestal made of wood or concrete before
use. There should be two holes 9mm in diameter on the pedestal, the space between which should be 124mm. Put filter pump on the pedestal and
fix them together by fasten the bolts and nuts. All the pedestal parts should weigh over 18kgs at least to prevent the pump from accidental falling.