3. Technical specifications

Model
Energy efficiency class
Rated capacity / rated current
EN
Chosen capacity / current
Electrical connection
Min. required cable size
Hot water (l/min)
max. at ∆t = 28 K
max. at ∆t = 38 K
Rated volume
Type
Heating system
Required spec. water
resistance @ 15 °C
Spec. electrical conductivity
Inlet temperature
Flow rate to switch on – max. flow rate
Pressure loss
Temperature choice
Water connection
Weight (when filled with water)
VDE class of protection
Noise level test certificate
Type of protection / safety
*) The declaration complies with the EU regulation No 812/2013
1) Maximum applicable cable size is 10 mm
2) Mixed water
3) Flow rate limited to achieve optimum temperature rise
4) Without flow regulator

4. Dimensions

18 kW (26 A)
1)
4,0 mm
9,2
2)
6,8
2
231
170
100
DEX ELECTRONIC MPS®
18 kW..27 kW (26 A..39 A)
21 kW (30 A)
3~ / PE 380..415 V AC
2
4,0 mm
2
10,7
2)
7,9
Pressure type 1,0 MPa (10 bar)
Bare wire heating system IES ®
≥ 1100 Ωcm
≤ 90 mS/m
2,5 – 8,0 l/min
0,2 bar bei / at 2,5 l/min
20 °C – 60 °C
PA-IX 6762/I
Dimensions in mm
231
22
A *
)
24 kW (35 A)
6,0 mm
2
12,3
2)
9,0
2)
0,4 l
≤ 70 °C
3)
1,3 bar bei / at 9,0 l/min
4)
G ½"
3,70 kg
I
IP25
27 kW (39 A)
3~ / PE 400 V AC
6,0 mm
2
13,8
2)
10,2
2)

Quicklinks ausblenden: