Registration / programming
Function
Limitation of traffic
Incoming and outgoing calls can be made.
Only incoming calls can be received.
Only outgoing calls can be made. This setting is useful, for example,
if you have connected an entrance intercom to the DECT Box to
prevent exchange calls ringing on the entrance intercom.
Factory setting: 0
Connection of calls
Internal/external call connection. A digit must be dialled to distinguish
whether a call is to be connected within the base station or externally.
This setting is not recommended if parameter 42 is set to 0.
Internal call connection. An internal connection is prepared immedia-
tely on lifting the handset. Only other cordless units on this base sta-
tion can be called; no exchange calls are possible. When connecting
an entrance intercom, this can be used to prevent the exchange line
being seized.
External call connection. An external connection is prepared imme-
diately on lifting the handset. By dialling the relevant code, internal
cordless units on this base station can also be called.
Factory setting: 2
Flash function
The flash key detection function (R key) of the DECT Box can be set
to the flash time of your connected device. (Please refer to the
operating manual for your device for this information).
For example, if the flash time of your device is 100 ms, this
corresponds to the setting "10".
The factory setting is 23, which corresponds to 230 ms.
Parameter Other input
code
12
70
0 #
70
1 #
70
2 #
71
0 #
71
1 #
71
2 #
72
Setting #