2
Registration / programming
Function
Internal dialling tone
An internal dialling tone is sounded immediately on lifting the hand-
set. The dialling tone is suppressed using this setting. This setting is
not recommended if parameter 71 is set to 0.
With this setting the internal dialling tone is sounded as a continuous
tone (425 Hz). This setting is useful if your base station is connected
to a direct trunk line.
With this setting the internal dialling tone is sounded as an interrupted
tone (450 Hz). This setting is useful if your base station is connected
to a phone system that also generates an interrupted dialling tone.
Factory setting: 0
Volume setting
The handset volume can be adjusted here for the acoustics of your
connected device in increments of 3 dB (1 = minimum, 6 = maximum).
Factory setting: 5
Display of caller's number / CLIP 44
The caller's phone number is not transmitted to the connected tele-
phone. The ring cadence of calls is controlled by the base station.
Please note: function 51 is not available.
Display of caller's number/CLIP. For CLIP transmission to the con-
nected phone the FSK type 1 protocol is used, which is common in
most countries. The ring cadence is fixed.
Display of caller's number/CLIP. For CLIP transmission to the con-
nected phone the DTMF protocol is used, which is common in the
Netherlands. The ring cadence of calls is controlled by the base
station.
Factory setting: 1
Parameter Other input
code
42
42
42
43
44
44
10
0 #
1 #
2 #
1...6 #
0 #
1 #
2 #