NOTICE
Installing a flow monitor in the circulation line is recommended so
that a failure message can be displayed. A lengthy interruption of
the bath water circulation can be prevented in this way.
Default settings:
Performance level:
Priming capacity:
Priming time:
Selectable performance levels:
Selectable priming time:
Low
n1
1
3
4
Power
BADU Pool technologies and solutions.
WG27.50.101-P
EN 16
n2
GREEN
2
SET
5
1
2
3
OK
0
Error
6
1 = 60 %
2 = 80 %
3 = 100 %
= 100 %
= 5 minutes
5 - 100 % (in 1 % steps)
0 - 10 minutes (in 1 min steps)
Priority
n3
User interface:
(1) LED display: displays the
current motor performance in %.
(2) "Set" button: used to enter the
programming mode or to reset
the control.
(3) Button "1/▼": used to select
the performance level/to change
in the programming mode
(4) Button "2/OK": used to select
the performance level/to save in
the programming mode.
(5) Button "3/▲": used to select the
performance level/to change in
the programming mode.
(6) Button "0": to stop the motor.
High
Stop
WG27.50.094-2-P