Herunterladen Inhalt Inhalt Diese Seite drucken

SICK IN4000 Direct Bedienungsanleitung Seite 64

Vorschau ausblenden Andere Handbücher für IN4000 Direct:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
en
Chapter 3
64
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Product description
LED
Meaning
indication
ν Yellow
Output switched
Ν Green
off; outside the
enable zone
(operating mode)
or inside the
enable zone
(adjustment mode)
Ν Yellow
Output switched;
Ν Green
inside the enable
zone (operating
mode)
∏ Yellow
Output switched
Ν Green
off; outside the
enable zone
(adjustment mode)
∏ Yellow
Internal or external
ν Green
error:
• e.g. cross-circuit
• e.g. short-circuit
(see section 7.2
"Troubleshooting"
on page 80)
between the
outputs
on an output to
supply or earth
Operating instructions
IN4000 Direct
Output state of the
outputs
OUT1
OUT2
(OSSD1)
(OSSD2)
0
0
1
1
0
0
0
0
0
1
1
0
8012183/YTC9/2016-04-12