RMD10.5T, RMD10.5XT
Faults are caused by a fault code with a warning symbol (
display.
Reset ERROR type faults manually:
➤ Press the control knob for 2 seconds.
✓ A beep sounds.
✓ The error has been reset.
RMD10.5, RMD10.5X
In the event of a fault, the LED warning symbol (
continuously and the LEDs flash according to the fault.
Reset ERROR type faults manually:
➤ Press the
button for 2 seconds.
✓ A beep sounds.
✓ The error has been reset.
Fault messages
Code
LEDs
W01
E03
W05
W06
EN
Fault
Temperature sensor in the
refrigerator compartment
defective
No connection between
power module and
display
AC power not connected
or AC voltage < 190 V
DC power not connected Warning
) in the middle of the
in the display lights up
)
Type
Solution
Warning
Replace the temperature
sensor.
Error
Check the connection
between the power
module and display.
Reset the error manually.
Warning
Connect the refrigerator to
AC or select a different
energy type, e.g. gas or
DC.
Connect the refrigerator to
DC or select a different
energy type, e.g. gas or
AC.