  • DEUTSCH, seite 55
DRY
TIMER indication
Indication of heater current
Functions
Heater DRY has 1 fixed temperature set-
ting (default temperature of 48° C) and an
advanced range of automatic switch off
functions after 1-5 hours. This makes the
product convenient and user-friendly - per-
fect for drying clothing and towels. The de-
fault heating temperature for the towel rail
can be set to any of the following values: 43,
48, 52, 55 or 60° C. A built-in temperature
sensor protects the towel rail from freezing
in situations where the temperature falls
below 5-7° C. The LED diode next to the
on/off button will flash recurrently, indicat-
ing that the anti-freeze protection is active.
EN
TIMER button
working state
On / off button
Heater use
The heater is turned on by pressing the
on/off button. The LED diode at the on/off
button lights up when the heater is on and
the regulator maintains the set heating
temperature. Attention: the heater control
panel turns the device on only when radia-
tor temperature is lower than the set tem-
perature (default temperature of 48° C).
On reaching the required temperature, the
heater will turn on recurrently to maintain
the set temperature only. This function al-
lows much lower energy consumption than
calculations based on the heaters nomi-
nal heat output might indicate. In the up-
per left part of the control panel, there is
a (TIMER) button which can be used to set
the automatic switch off time of the device.
Every subsequent pressing of the buttons
17