Fault
Water stream is uneven.
Inadequate or no flow of
detergent
Pressure does not build up
in the pump
High pressure pump is
knocking; manometer (op-
tion) is swaying wildly
The installation does not
start when switched on or
when pressing the remote
control (optional).
Pump starts during the
stand-by period and not
when the hand spray gun
is opened.
Installation does not
switch off.
Possible cause
Nozzle is blocked.
Amount of water supply is too low.
Dosage adjusted too low.
Nozzle is set to "High pressure".
Suction filter in the detergent tank is
dirty.
Detergent suck hose leaking.
Manual detergent dispensing valve
occluded, defective.
Nozzle is set to "CHEM"
Air in the high pressure pump
Suction site pipe leaking.
Not enough water
Sieve in the water inlet is dirty
High pressure hose leaking.
Piping leaking.
Flow regulator defective.
The valve in the pump is defective.
Vibration dampener is defective.
Water pump does not suck in ade-
quate air.
Detergent container is empty
Water flow temperature too hot.
Water flow blocked.
Valve plate or valve spring is defec-
tive.
Advance pump calcified or defective. Check advance pump.
Appliance switch is switched off
On-board electricity supply interrupt-
ed.
Pressure switch is defective
Motor protection switch was trigged
by overflow or loss of a phase of the
electricity supply.
Motor protection switch is set incor-
rectly.
Motor protection switch for controls
and advance pressure pump trig-
gered.
Control safety transformer defective.
Circuit board defective.
Pressure switch or pressure switch
cable defective.
Pump is drawing in air over the empty
detergent tank.
Pressure switch is defective.
Remedy
Clean the nozzle.
Check water supply.
Increase dose.
Set nozzle to "CHEM".
Clean the suction filter.
Replace suck hose.
Check; clean, replace, if required.
Set nozzle to "High pressure".
Ventilate the appliance (see "System start-
up")
Check screw fittings and hoses.
Ensure adequate water supply.
Clean sieve.
Replace high pressure hose.
Repair piping system.
Test flow regulator, repair.
Replace valve.
Replace vibration dampener.
Check suction system and remove leaks.
Refill detergent tank.
Lower water temperature.
Clean sieve in the water inlet, check the wa-
ter flow.
Replace parts
Turn it on.
Turn it on.
Replace pressure switch.
Check the voltage of the three phases.
Adjust according to circuit diagram.
Check motor protection switch.
Examine the cause, replace the control
safety device.
Check circuit board, replace if required.
Replace the pressure switch or cable.
Refill the detergent tank, ventilate suction
line.
Replace pressure switch.
8
-
EN
of whom
Operator
Operator
Operator
Operator
Operator
Customer Service
Customer Service
Operator
Operator
Operator
Operator
Operator
Customer Service
Customer Service
Customer Service
Customer Service
Operator
Operator
Operator
Operator
Operator
Customer Service
Operator
Operator
Operator
Customer Service
Electrician/ Cus-
tomer Service
Electrician/ Cus-
tomer Service
Electrician/ Cus-
tomer Service
Electrician/ Cus-
tomer Service
Customer Service
Customer Service
Operator
Electrician/ Cus-
tomer Service
25

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis