Herunterladen Inhalt Inhalt Diese Seite drucken

Interrupting Operation; Finish Operation - Kärcher HD 22/15-4 Cage Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Turning on the Appliance
Open tap.
Plug in the main plug.
Set the appliance switch to "I".
Press safety catch on the handgun to re-
lease it and pull lever.
High pressure operation
Danger
Long hours of using the appliance can cause
circulation problems in the hands on account
of vibrations.
It is not possible to specify a generally valid
operation time, since this depends on sever-
al factors:
– Proneness to blood circulation deficien-
cies (cold, numb fingers).
– Low ambient temperature. Wear warm
gloves to protect hands.
– A firm grip impedes blood circulation.
– Continuous operation is worse than an
operation interrupted by pauses.
In case of regular, long-term operation of the
device and in case of repeated occurrence
of the symptoms (e.g. cold, numb fingers)
please consult a physician.
Warning
The handgun is subjected to a recoil force
when the water jet is discharged. Make sure
that you have a firm footing. Hold the hand-
gun and spray lance firmly.
The appliance is equipped with the following
nozzles:.
– Power nozzle, 25° spray angle
– Rotary nozzle
Power nozzle
– Carrying out the most common cleaning
tasks
Rotary nozzle
– For strong contaminations
16
English
Set working pressure and flow rate
Working pressure or quantity can be adjust-
ed either at the pump unit or at the hand
spray gun.
Do not reduce the pressure/ quantity simul-
taneously at both the regulators. The follow-
ing procedure is to be followed compulsorily:
Pressure/ quantity regulation at the
pump unit
Set (+) working pressure and quantity to
maximum at the hand spray gun.
Pull the lever on the handgun.
Set the working pressure and quantity by
turning the pressure/ quantity regulation
mechanism at the pump unit.
The working pressure can be read from
the manometer.
Pressure/ quantity regulation at the
hand spray gun
Set the pressure/ quantity regulation at
the pump unit to maximum working pres-
sure and quantity by turning in clock-
wise direction.
Set (+/-) the working pressure and quan-
tity by turning the pressure/ quantity reg-
ulation mechanism at the hand spray
gun.
Pull the lever on the handgun.

Interrupting operation

Release the lever on the handgun.
Use the safety catch to secure the hand-
gun lever.
Store the hand spray gun and spray pipe
in the accessory mount.

Finish operation

After operating the water using saline
water (sea water), open the hand spray
gun and rinse the appliance for at least 2
- 3 minutes using tap water.
Release the lever on the handgun.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hd 17/20-4 cage

Inhaltsverzeichnis