Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data For 1 Motor - G-U ELTRAL KS 30/40 EASY TR Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5

Technical data for 1 motor

Type
Push* / pull force
Travel (adjustable)
Nominal voltage
Current consumption at nominal load
Power consumption at nominal load
Running speed (unloaded)
Double electrical insulation
Duty ratio (power-on time)
Ambient temperature
Protection class
Connection of several drives in parallel
Limit stop switch at opening
Limit stop switch at closing
Connecting cable
Dimensions Height x Depth x Width
Weight
The specifications stated in this table are not binding and may be changed without prior notice.
*
Force-travel diagram
02.2013 | G27021 | Printed in Germany
110 V / 230 V
* (see force-travel diagram) / 250 N
185, 305 mm
110 V / 230 V~
50/60 Hz
0.18 A
~30 W
13.5 mm/s
Yes
30% (10 min)
-5°C to +65° C
IP30
Yes (max. 10 drives)
Electronic
Load-depending control
approx. 1 m,
core 3x 0.75 mm²
34 mm x 56 mm x 355 mm
approx. 0.84 kg
Push force [N]
24 V
24 V DC
0.8 A
~18 W
12.8 mm/s
Low voltage
approx. 1 m,
core 2x 0.75 mm²
approx. 0.82 kg
Travel [mm]