Annual requirement
Reagents and wear
Measurement interval 5
parts
minutes
Reagents (A, B,
13 x LCW 802
additional components)
Null solution
1 x LCW 804
Standard solution
depending on
measurement range
AMTAX inter 2 -
4 x LCW 862
0.02–2.00 mg/L
(0.5 mg/L NH
AMTAX inter 2 -
1 x LCW 803
0.1–20 mg/L
(5 mg/L NH
AMTAX inter 2 -
1 x LCW 808
2–80 mg/L
(35 mg/L NH
Cleaning solution
1 x LCW 819
(2 x 250 mL)
Wear parts set
1 x LZV 281
(1 channel)
Additional for the 2
+ 1 x LZV 278
channel version
Measurement interval
10 minutes
6 x LCW 802
1 x LCW 804
4 x LCW 862
–N)
(0.5 mg/L NH
–N)
4
4
1 x LCW 803
–N)
(5 mg/L NH
–N)
4
4
1 x LCW 808
–N)
(35 mg/L NH
–N)
4
4
1 x LCW 819
1 x LZV 281
+ 1 x LZV 278

Warranty and Liability

The manufacturer warrants that the supplied product is free of material
and manufacturing defects and undertakes to repair or replace any
defective parts at zero cost to the owner.
The warranty period is 24 months. If a maintenance contract is taken out
within 6 months of purchase, the warranty period is extended to 60
months.
For defects to which the lack of assured properties also counts, the
supplier is liable with exclusion of further claims as follows: All those
parts that, within the guarantee period calculated from the day of the risk
transfer, can be demonstrated as a result of circumstances prior to the
risk transfer, in particular due to defective design, inferior materials or
defective execution, to be unusable or whose usability is significantly
impaired, are improved or replaced in accordance with the choice of the
supplier free of charge. The identification of such defects must be
notified to the supplier immediately, however at the latest seven days
after the identification of the fault, in writing. If the customer omits this
notification, the performance is considered approved despite the defect.
Further liability for any direct or indirect damages is not accepted.
If instrument-specific maintenance and servicing work prescribed by the
supplier is to be performed within the warranty period by the customer
(maintenance) or by the supplier (servicing) and these requirements are
not met, claims for damages resulting from non-compliance with these
requirements are rendered void.
Any further claims, in particular claims for consequential damages,
cannot be made.
Wear and damage caused by improper handling, incorrect installation or
non-designated use are excluded from this clause.
English 121