FAULT INDICATIONS
No or too little cleaning agent
solution on the floor
Fill the tank with the cleaning agent
–
solution
Check that the tank is firmly fitted
–
Unsatisfactory cleaning results
Replace worn rotary brooms
–
Check that the rotary broom or the
–
pads match the application on
hand.
Rotary brushes do not turn
Remove jammed foreign bodies
–
The appliance is overloaded, the
–
overcurrent protection switch
triggered, allow it to cool down. The
appliance is operable again after
approx. 30 s.
Use rotary brushes suitable for job
–
Mains circuit breaker triggers
when the cleaner is switched on
Ensure adequate mains fuse
–
protection (16 A time-lag) or use
starting current limiter
Switch off other consumers or use
–
other power circuit.
Cleaner runs unevenly or vibrates
heavily
Check the proper fit of the rotary
–
brooms
Exchange the right for the left hand
–
rotary broom and vice versa
Soak the rotary brooms in hot water
–
(approx. 80 °C) for approx. 15 min.
If fault cannot be rectified, have
unit checked by After-Sales
Service.
TECHNICAL DATA
Mains fuse
(slow)
16 A
Power drive
Nominal
voltage *EU
230 V (1~50Hz)
Rated
voltage *BR
230 V (1~60Hz)
Nominal power consumption
Total
2,1 kW
–
Brush motor
2,05 kW
–
Spray pump
0,05 kW
–
Area performance
(theoretical)
450 m²/h
Brushes
Number
2 pieces
Diameter
95 mm
Tank
Capacity
3 Litres
option
10 Litres
Dimensions and weights
Length
530 mm
Width
450 mm
Height without protective
bracket
180 mm
Empty weight
30 kg
Working width
400 mm
Protection class
I
Noise emission
Sound pressure level
(EN 60704-1)
70 dB(A)
Machine vibration
Total vibration value
(ISO 5349)
upper limbs
< 1m/s²
BR VS 400