Installation - Butt weld spigots:
DANGER
Vapor fumes from PFA welding can
cause health related issues!
® Risk of damage to respiratory tracts,
caustic burns / poisoning!
Weld PFA components in a well-
G
ventilated area.
Only use approved welding equipment.
G
Wear protective gear.
G
Breathing masks are recommended.
G
Welding may only be carried out by
G
qualifi ed trained personnel.
Important:
Poor or careless welding
procedures and processes will void
warranty and cause damage to the
product. The results of poor welding
procedures are valve leakage and
deformation.
Adhere to good welding practices!
Installation - Flare and space saver
connections:
1. Also refer to GEMÜ FlareStar
and GEMÜ fl are and assembly
instructions for preparation and
connection of fl are connections!
2. Push the fl ared tube onto the fl are
connection.
3. Screw on union nut.
4. Use connection fi ttings resistant to and
suitable for the ambient conditions.
Installation - PrimeLock connections:
1. Preparation of the tube by mounting
the sleeve (observe manufacturer's
instructions:
www.entegrisfl uidhandling.com /
Product.aspx?G=1905.
2. Push together PrimeLock connection
with prepared tube.
3. Tighten PrimeLock union nut.
Observe appropriate regulations for
connections!
C67
After the installation:
Reactivate all safety and protective
G
devices.
Check the function and tightness of
G
installed valves at regular intervals.

11.2 Operation

Optical position indicator
brochure
®
Rising handwheel!
® Danger of crushing fi ngers.
32 / 40
Valve open
CAUTION
Handwheel can become hot
during operation!
® Risk of burns!
Ensure protective gloves
G
are worn when operating
handwheel.