5. Settings

5-2-3. Resetting the Detailed Settings

Power ON
Current value display
Detailed
settings
Minimum
display
resolution
Display
switching
Axis label
switching
Scaling
Compensation
value
Flicker control
Sleep
or

Start of operation

* When the segmented error compensation value is set,
the unit switches to reference point acquisition mode.
5-6
(E)
(General-purpose Applications and Milling Machine Function)
* The setting in parentheses ( ) is the factory setting.
*
1
Select axis
Use
and
Performed for each axis.
2
Select axis
Use
to select setting content
Performed for each axis.
3
Select axis
Use
to select setting content
Performed for each axis.
4
Enter the setting value
5
Use
to select the setting (compensation), and then set each option
Select axis
Enter the compensation value
Enter the
position
6
Use
to select setting content
7
Use
to select setting content
(When the minimum display resolution is 0.001 mm)
indicates the process when the setting does not
be changed.
to select setting content
Enter the
compensation value
is displayed,
1 Setting at
measuring unit
resolution or
higher/Diameter
display at
measuring unit
resolution
(except for
angle)/Polarity
2 IN-1/IN-2/IN-3/
IN -
3 X/Y/Z
4 0.100000 -
9.999999
5 OFF/LIN Err/
SEG Err
* See Part 5-5,
"Compensation".
6 OFF/1/2
7 OFF/1/5/10/30/
60
or
LH71

Werbung