5-5-2. Segmented Error Compensation

In this compensation, the segments are determined, and mechanical error is compensated for each segment.
This is only effective in cases where you use a measuring unit with a reference point.
The segmented error compensation is set using the process below.
Measure the
compensation value
(error)
When the segmented error compensation value is set, the unit automatically switches to reference point
acquisition mode after the detailed settings are finished, the power is turned on, or an error is reset. (See Part
7-2-9, "Reference Point Mode (How to Use the Measuring Unit with a Reference Point)".)
Measurement of machine precision
To perform the segmented error compensation, measurement is made to find the amount of error and where
it occurs on the machine. Be sure to measure the error amount with the reference point position of the
measuring unit at 0.
Number of points that can be input : 32
Compensation amount
Compensation
amount
Measuring unit reference point position =
Laser interferometer measurement zero point
[Notes on precision measurement]
The precision can be measured based on the measuring unit standard or laser standard. The measuring unit
standard is more accurate, and so measurement of the measuring unit standard is recommended.
Measuring unit standard : If the counter unit shows 100.000 mm when the display on the standard measuring
Laser standard
<Measurement example: Measuring unit standard>
Input point
Values shown on
counter unit
Laser display value
Compensation amount
LH71
Set the segmented error
t
compensation value
("Detailed Settings")
: up to ±600 um
(can be entered in measuring unit input resolution units)
unit (laser) shows 100.005, the compensation amount is +0.005 mm.
: If the display on the standard measuring unit (laser) shows 100.000 mm when
the counter unit shows 100.010, the compensation amount is _0.010 mm.
1
2
_200.000
_100.000
_200.005
_99.995
_0.005
0.005
+
Acquire the
t
reference point
Input point
Error
Error
Laser interferometer
measurement
Counter display
value
ex :
Therefore, you would input an error
of 0.045.
3
4
100.000
200.000
100.010
200.005
0.010
0.005
+
+
ε
ε
ε
:
x =
M
ε
:
M
ε
:
c
ε
x = 156.000 – 155.955
= 0.045 mm
(Unit: mm)