OPERATION PROCEDURE FOR SWING LOUVER ADJUSTMENT
1. When the SWING LOUVER switch is pressed,
the swing louver starts its operation. The range
of the swinging angle is approximately 70°
from the horizontal position to the downward
position. When mark "
indicates the operation of the louver
continuously.
2. When the swinging operation of the louver is
Setting
not required, press the SWING LOUVER
Swing
switch again. The louver is stopped at an angle
Louver
indicated by the direction of the mark "
3. Discharge air angle is fixed (at 20° for RCI
series and 40° for RCD series) during start-up
of heating operation and defrosting operation
when thermostat is ON.When the outlet air
temperature reaches higher than
approximately 30 °C, swinging of louvers is
started.
1. In the case of cooling and dry operation,
discharge air angle can be changed at 5
positions. In the case of heating
operation, it can be changed at 7
positions
2. To fix the louver position, first press the
SWING LOUVER switch to start the
louver swinging, and then press the
SWING LOUVER switch again when the
louver reaches the required position.
3. Discharge air angle is fixed (at 20° for
RCI series and 40° for RCD series)
during start-up of heating operation and
defrosting operation when thermostat is
ON.When the outlet air temperature
Fixing
exceeds approxima-tely 30 °C, the swing
of
louvers activate.
Louver
4. When the louvers are fixed at an angle
55° RCI, 65° RCD or 70° both during
heating operation and the operation mode
is changed to cooling operation, louvers
will be automatically fixed at an angle 45°
RCI, 60° RCD
NOTE:
There exists a time lag between the actual
angle of the louver and the liquid crystal
indication. When the SWING LOUVER
switch is pressed, the louver will not stop
immediately. The louver will move one
extra swing.
RCI (4-Way Cassette Type)
Indication
Louver Angle
(approx.)
" is moving, it
Cooling Dry
Heating
Angle Range
Recommended Angle
".
RCD (2-Way Cassette Type)
Indication
Louver Angle
(approx.)
Cooling Dry
Heating
Angle Range
Recommended Angle
RPK (Wall Type)
Indication
Louver Angle
(approx.)
Cooling Dry
Louver Angle
(approx.)
Heating
Angle Range
Recommended Angle
RPC (Ceiling Type)
Indication
Louver Angle
(approx.)
Cooling Dry
Heating
Angle Range
Recommended Angle
REMOTE CONTROLLER OPERATION
Approx.
Approx.
Approx.
Approx.
20°
25°
30°
35°
Angle range
Angle range
Approx.
Approx.
Approx.
Approx.
40°
45°
50°
55°
Approx.
Approx.
Approx.
Approx.
35°
40°
45°
50°
Approx.
Approx.
Approx.
Approx.
40°
45°
50°
55°
Approx.
Approx.
Approx.
Horizontal
15°
30°
40°
5
7
Approx.
Approx.
Approx.
45°
55°
70°
Approx.
Approx.
Approx.
60°
65°
70°
Approx.
Approx.
Approx.
55°
60°
70°
Approx.
Approx.
Approx.
60°
65°
70°
Approx.
Approx.
Approx.
50°
60°
80°

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ras-4fsvneRas-5fsvne

Inhaltsverzeichnis