15
Save: Toggles the display between an active display and one
of 15 stored memory locations.
Shift/Save: Initiates a save routine to store the currently displayed trace.
By saving to a memory location, traces can be recalled later.
MENU
The MENU includes all those settings that would not be accessed in
daily use. To enter this mode press the MENU key. (13)
TEST RATE
PULSE WIDTH
PULSE HEIGHT
AVERAGING
ZERO (ns)
POWERDOWN
DISPLAY (min)
LANGUAGE
VF UNITS
DISTANCE UNIT
50/60 Hz FILTER
MENU
[1/s] [3/s]
Dependant on range, refer to
specification
[3V] [5V] [14V]
[x1] [x2] [x3] [x4] [x5]
[0ns to 50ns in steps of 1ns]
[5min] [10min] [15min]
[1min] [2min] [5min]
[ENGLISH, ...]
[RATIO] [m/us] [ft/us]
[m] [ft] [ns]
[ON] [OFF]
7