CFW-08 - QUICK PARAMETER REFERENCE
Parameter
Function
Digital Output(s)
(3)
P277
Relay Output RL1 Function
(3) (6)
P279
Relay Output RL2 Function
P288
Fx Frequency
P290
Ix Current
Inverter Data
P295
(3)
Rated Inverter
Current (I
)
nom
(3)
P297
Switching Frequency
DC Braking
P300
DC Braking Time
P301
DC Braking Start Frequency
P302
DC Braking Current
Skip Frequencies
P303
Skip Frequency 1
P304
Skip Frequency 2
P306
Skip Band Range
Serial Communication Interface I
P308
(3)
Inverter Address
Flying Start and Ride-Through
(3)
P310
Flying Start and Ride-Through 0 = Inactive
(*) It is not possible to set P297 = 7 (15 kHz) in vector control mode (P202 = 2) or when the external serial keypad (HMI-CFW08-RS) is used.
12
Adjustable Range
0 = Fs > Fx
1 = Fe > Fx
2 = Fs = Fe
3 = Is>Ix
4 and 6 = Not Used
5 = Run
7 = No Fault
0 = Fs > Fx
1 = Fe > Fx
2 = Fs = Fe
3 = Is > Ix
4 and 6 = Not Used
5 = Run
7 = No Fault
Fx and Ix
0.00 to P134
0 to 1.5xI
nom
300 = 1.0 A
312 = 22 A
301 = 1.6 A
313 = 24 A
302 = 2.6 A
314 = 28 A
303 = 2.7 A
315 = 30 A
304 = 4.0 A
316 = 33 A
305 = 4.3 A
306 = 6.5 A
307 = 7.0 A
308 = 7.3 A
309 = 10 A
310 = 13 A
311 = 16 A
4 = 5.0
5 = 2.5
6 = 10
(*)
7 = 15
0.0 to 15.0
0.00 to 15.00
0.0 to 130
P133 to P134
P133 to P134
0.00 to 25.00
1 to 30 (Serial WBus)
1 to 247 (Modbus-RTU)
1 = Flying Start
2 = Flying Start and
Ride-Through
3 = Ride-Through
Factory
Unit
Setting
Setting
7
-
0
-
3.00
Hz
1.0xI
A
nom
-
According
to the
inverter
model
4
kHz
0.0
s
1.00
Hz
0.0
%
20.00
Hz
30.00
Hz
0.00
Hz
1
-
0
-
User
Page

Werbung

Inhaltsverzeichnis
loading