Herunterladen Inhalt Inhalt Diese Seite drucken

Eliwell EWCFW-08 Bedienungsanleitung Seite 10

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

CFW-08 - QUICK PARAMETER REFERENCE
Parameter
Function
P236
Analog Input AI1 Offset
(6)
P238
Analog Input AI2 Gain
(3)(5)(6)
P239
Analog Input AI2 Function
(6)
P240
Analog Input AI2 Offset
P248
Analog Inputs Filter
Time Constant
Analog Output
(6)
P251
Analog Output
AO Function
(6)
P252
Analog Output AO Gain
P253
Analog Output AO Signal
Digital Inputs
(3)
P263
Digital Input DI1 Function
(3)
P264
Digital Input DI2 Function
(3) (7)
P265
Digital Input DI3 Function
(**) Only available on the control board A2 (refer to item 2.4). For programming instructions, please, refer to the parameter P235 detailed
description.
10
Adjustable Range
-999 to +999
0.00 to 9.99
0 = (0 to 10) V/(0 to 20) mA/
(**)
(-10 to +10) V
1 = (4 to 20) mA
2 = DI6 PNP
3 = DI6 NPN
4 = DI6 TTL
5 = PTC
-999 to +999
0 to 200
0 = Output Frequency (Fs)
1 = Input Reference (Fe)
2 = Output Current (Is)
3, 5, 8 = Not Used
4 = Motor Torque
6 = Process Variable (PID)
7 = Active Current
9 = PID Setpoint
0.00 to 9.99
0 = (0 to 10) V/(0 to 20) mA
1 = (4 to 20) mA
0 = No Function or General
Enable
1 to 7 and 10 to 12 =
General Enable
8 = Forward Run
9 = Start/Stop
13 = FWD Run Using
Ramp 2
14 = On
0 = Forward/Reverse
1 = Local/Remote
2 to 6 and 9 to 12 = Not Used
7 = Multispeed (MS2)
8 = Reverse
13 = REV Run - Ramp 2
14 = Off
0 = Forward/Reverse
1 = Local/Remote
2 = General Enable
3 = JOG
4 = No External Fault
5 = Increase E.P.
6 = Ramp 2
7 = Multispeed (MS1)
8 = No Function or
Start/Stop
9 = Start/Stop
10 = Reset
Factory
User
Unit
Setting
Setting
0.0
%
1.00
-
0
-
0.0
%
10
ms
0
-
1.00
-
0
-
0
-
0
-
10
-
Page