Herunterladen Inhalt Inhalt Diese Seite drucken

CST/BERGER Theodolite DGT 2 Originalbetriebsanleitung Seite 22

Vorschau ausblenden Andere Handbücher für Theodolite DGT 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Function Buttons
– Switch the display on and press the respective
button to select the desired option.
Button
Function
Button for counting direction of the hori-
R/L
zontal circle:
Clockwise direction ("R") or
anticlockwise direction ("L")
Hold button for reading of horizontal cir-
HOLD
cle:
For setting or releasing the current hori-
zontal-circle value.
When setting, the value remains
unchanged when turning the measuring
tool and the angle indication flashes.
On/Off button for llumination of display
and crosshair
Button for angle indication in grad ("G")
V / %
or %
Button for zeroing the horizontal circle:
OSET
Sets the horizontal indication to zero
On/Off button for display 20
only for DGT 2
The DGT 2 can be connected with an electronic dis-
tance measuring tool. Control takes place via second-
ary assignment of the operating panel buttons.
Configuring the Measuring Tool
– Switch the display on.
"Switching On the Display" see page 21.
– Press the R/L and V/% buttons at the same time.
The standard indication is shown on the display.
– To make the desired alterations, press the buttons
described in the following.
– When all alterations have been entered, press the
R/L and V/% buttons at the same time again.
A long audio signal sounds and the settings are
shown on the display.
22 | English
Button
Alteration/Indication
Changes the steps for the angle indica-
R/L
tion:
Step range selectable in 5'' or 10''.
Changes the angle indication for horizon-
V / %
tal and vertical angles from 360° to 400
grad.
Changes the auto power-off duration of
HOLD
the display:
0
Auto power-off inactive
10 Power-off after 10 seconds
30 Power-off after 30 seconds.
Changes the zero points of the vertical-
OSET
angle circle:
ua Zenith angle
ub Vertical angle
uc Height angle
(see figure D)
Switches the audio signal that sounds at
0°, 90°, 180° and 270° on or off.
only for DGT 2:
FUNC
Activates the compensator function
only for DGT 2:
Using the Compensator
For precise angle measuring, the compensator's incli-
nation sensor must be activated. This automatically
compensates vertical deviations of the measuring
tool.
2 610 A15 111 • 23.6.09

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Theodolite dgt 10

Inhaltsverzeichnis