Connection steps
Step 1: Place holes ① of the connector on the two screw holes inside the bot-
tom of frequency converter and tighten two screws (M5 x 12).
Step 2: Insert the shielded cables through component ② of the connector with
the shielding layer reliable contact with the metal.
Step 3: Tighten four screws of the accessories (component ③: M4 x 45).
Step 4 (optional): Insert the shielded cables of STO through component ④ of
the connector with the shielding layer reliable contact with the metal.
Step 5 (optional): Tighten two screws of the accessories (component ⑤: M4 x
12).