EFC x610 Series
12.4.4 Output Frequency Limitation
Direct output frequency limitation
Code
E0.08 Maximum output frequency
E0.09 Output frequency high limit
E0.10 Output frequency low limit
Maximum output frequency
●
The allowed maximum output frequency of the frequency converter.
Output frequency high limit
●
The allowed maximum output frequency according to the requirements in ac-
tual applications.
Output frequency low limit
●
The allowed minimum output frequency according to the requirements in ac-
tual applications.
Behavior at low speed running
Code
E0.15 Low speed running setting
E0.16 Low speed frequency hysteresis
By default, the frequency converter runs at 0 Hz when the output frequency is
lower than [E0.10] 'Output frequency low limit'.
[E0.15] = 0: Running at 0.00 Hz
●
Fig. 12-21: Running at 0 Hz
DOK-RCON03-EFC-X610***-IT06-EN-P
Name
50.00...400.00 Hz
[E0.10]...[E0.08] Hz
0.00...[E0.09] Hz
Name
0: Running at 0.00Hz
1: Running with low limit fre-
quency
0.00...[E0.10] Hz
Functions and Parameters
Setting range
Setting range
Bosch Rexroth AG
Default
Min.
Attri.
50.00
0.01
Stop
50.00
0.01
Run
0.00
0.01
Run
Default
Min.
Attri.
0
–
Stop
0.00
0.01
Stop
157/421